Skip to content
VFDMatch.comENGINEERING SOURCING DIRECTORY

HPMONT

Industrial motor drives and a dedicated elevator-control business.

HPMONT was founded in March 2011 in Shenzhen. Its products connect two areas of engineering: industrial motor control and elevator or escalator systems. HD30 documentation gives detailed industrial ratings and application interfaces, while HD5L, HD30-ES/ES1 and the MONT controllers address the separate requirements of carrying systems.

HPMONT HD30 product reference
HD30 · manufacturer product reference
Founded
March 2011[2]
Shenzhen location
Xili Dakan, Nanshan district[1][3]
Manufacturing milestone
New manufacturing centre opened in March 2023[2]
Industrial reference
HD30 · separate G and P ratings[5]
01

From the first HD products to a new manufacturing centre.

HPMONT’s published milestones show the development of the Shenzhen operation and its technical partnerships.

  1. 2011

    Established in March

    The corporate history records the company’s founding and the introduction of HD-series products in December.[2]

  2. 2012

    Barcode tracking and joint training

    HPMONT records a BTS barcode-tracking system in March and a Xi’an Jiaotong University postgraduate joint-training base in July.[2]

  3. 2017

    Wuhan University of Technology cooperation

    The history records a joint training initiative with the university’s information-engineering institute.[2]

  4. 2023

    Manufacturing and modernisation services

    The company records a new manufacturing centre entering use in March and an international elevator-modernisation service centre opening in Malaysia in June.[2]

The company and its premises

The official introduction names Shenzhen Hpmont Technology Co., Ltd. and publishes Building 28, Wangjingkeng Industrial Zone, Xili Dakan, Nanshan district as its contact address. The Shenzhen 2024 fifth-batch safety-standardisation review list names 深圳市海浦蒙特科技有限公司 at entry 8 in Xili, Nanshan. This public record identifies the Chinese enterprise behind the brand and concerns company-level workplace safety standardisation.[1][3]

02

Two businesses share motor-control expertise.

Industrial automation and elevator control have their own product groups and system interfaces.

Industrial control

HPMONT identifies industrial control as a core technology. HD30 is its general industrial vector-drive reference, with process PID, simple PLC sequences, wobble operation and length control. The product page also describes a custom user menu, so commonly used parameters can be collected in Group U. These functions serve machinery with different process and operator requirements.[1][4]

Carrying systems and technical cooperation

The elevator catalogue separates door controllers, drive controllers, integrated controllers, control panels, emergency devices and regenerative units. The company introduction also describes university technical cooperation and joint training with Xi’an Jiaotong University and Wuhan University of Technology. These are published aspects of HPMONT’s engineering organisation, alongside the manufacturing and tracking milestones in its history.[1][2][9]

03

One HD30 frame can have two duty ratings.

The July 2021 V2.4 manual identifies G as general duty and P as fan-and-pump duty.

Swipe horizontally to compare all columns.

380–460 V modelG motor / output currentP motor / output current
HD30-4T5P5G/7P5P5.5 kW / 13 A7.5 kW / 17 A
HD30-4T7P5G/011P7.5 kW / 17 A11 kW / 25 A
[5]

Current and overload belong to the selected duty

The manual’s printed page 6 lists the two current ratings for each of these models. Its performance table specifies G overload at 150% of rated output current for two minutes and 180% for ten seconds; P is listed at 130% for one minute and 150% for ten seconds. The higher fan/pump kilowatt value therefore accompanies a different overload basis. Select against the motor current and load cycle, retaining the G/P designation in the proposal.[5]

Keep the edition visible

The V2.4 revision record is dated July 2021 and states applicability to software after version 3.09. The current web page lists a 380–460 V headline range up to 450 kW, while the separate mining article reports a 630 kW HD30 installation. That reported installation should have its own rating and configuration confirmed; it does not extend the current product page’s table automatically.[4][5][6]

04

HD30-EIO and HD30-PIO have different signal roles.

The option names are similar, but the manual describes different applications.

EIO: extend the general signals

Chapter 8 describes HD30-EIO as an extension for analogue input, digital input and digital output. The manual ties additional DI7–DI9 inputs and additional relay functions to use of this card. Its options also include named PROFIBUS, DeviceNet and CAN bus modules. A control-system proposal should identify the signals and actual fitted module, rather than assuming the standard terminals cover every connection.[5]

PIO: an injection-moulding interface

Printed page 128 describes HD30-PIO as a card developed specifically for injection-moulding machines. It provides two isolated sampling channels, each selectable for 0–24 V voltage or 0–1 A current input, referenced to AI3 and AI4. This is a concrete example of the industrial application scope: the machine’s existing analogue command and its signal range determine whether this interface is appropriate.[5]

05

The mining account covers several different motor duties.

HPMONT’s August 2023 report follows crushers, lifting equipment, grinding mills and fans through their different operating demands.

Starting torque: crushers and mine lifting

The article reports a 630 kW HD30 in coal crushers at a Shandong coking plant and a 315 kW drive at a Yunnan copper-mine lifting site. It discusses open-loop torque-vector control and low-frequency starting torque. These are separate installations with different mechanisms. For a new crusher or hoist, identify the actual starting load, load cycle, brake requirements and drive configuration rather than transferring a case rating to a new motor.[6]

Continuous duty: grinding and pumping

The same account identifies 315 kW ball-mill applications in Suichuan and Shanxi, vertical mixing mills at 400/355 kW and six 220 kW inverters for a mining-pump application in Eshan. The mill discussion emphasises sustained large-load operation. These examples give the industrial range more context than a generic sector list: the operating cycle and cooling conditions are part of the selection.[6]

A rotating fan has a different restart condition

For ventilators, the article discusses large inertia and speed-tracking restart before the motor has coasted to zero; it identifies a 355 kW Yunnan application. Treat restart behaviour and the process’s permitted stopping time as separate requirements from the crusher’s starting torque or a mill’s continuous load. The report is HPMONT’s application account, not a VFDMatch performance test.[6]

06

The industrial drive needs a protected installation environment.

The HD30 manual specifies the cooling-air and environmental basis for its ratings.

IP20 and temperature derating

V2.4 gives IP20 and indoor use protected from direct sunlight, corrosive or flammable gases, oil mist, dripping water and salt. Its environment table specifies −10 to +40 °C operation and a maximum of 50 °C, with rated output current reduced by 2% for each degree above 40 °C. The altitude rule reduces current by 1% for each 100 m above 1000 m. Use the air reaching the drive, including the conditions inside its cabinet, when defining the installation.[5]

Agree the delivered installation scope

The manual shows peripheral power accessories such as input/output reactors, filters and braking components. The offer should state which accessories, communication card, keypad and enclosure arrangement are supplied. For a mining application, include dust control, ventilation, load cycle and restart behaviour in the brief. For an injection-moulding interface, include the controller’s actual analogue ranges.[5][6]

07

Elevator and escalator controllers keep their own product identities.

HPMONT’s carrying-system pages describe functions tailored to passenger movement and existing controllers.

HD5L: elevator-drive integration

The HD5L page describes use in new elevator drives and replacement of an old controller. Features include programmable I/O, starting-torque compensation with encoder cards, S-curve acceleration/deceleration, even frequency-division output and a built-in braking unit. Those functions belong to HD5L and its selected feedback arrangement. They should be matched to the elevator’s existing controller, motor and complete system design.[7]

HD30-ES/ES1: escalator-specific behaviour

The separately listed escalator controller accepts entrance-sensor signals for energy-saving operation and offers programmable I/O. The page also describes automatic carrier-frequency reduction based on module temperature. Beyond these drives, the catalogue lists MONT70, MONT71 and MONT72 integrated controllers, MONT20 door control and a MONT90 four-quadrant integrated controller. A complete modernisation project can therefore involve multiple control components with distinct responsibilities.[8][9]

08

Explore HPMONT products on VFDMatch.

Continue with the published series or exact model before preparing your request.

HPMONT HD30
HPMONT / PRODUCT SERIES

HD30

Hpmont maintains dedicated manuals for HD30 vector drives and separately named application variants. The exact suffix matters when selecting documentation for a project.

A brief that makes the next reply useful.

Copy these prompts and add your project details. Keep the same scope when comparing quotations.

  1. Industrial machine, elevator or escalator
  2. Motor current, operating cycle and full controller model
  3. HD30 G/P duty and applicable software/manual
  4. Analogue signals, network modules and feedback
  5. Braking, enclosure ventilation and installation altitude
  6. Existing controller and complete modernisation scope
Send an inquiry

Buyer questions

When was HPMONT founded?

Its official milestone page records establishment in March 2011.

Does HD30-PIO simply add more general I/O?

It is specifically described as an injection-moulding interface, with two isolated channels selectable for 0–24 V or 0–1 A sampling.

Can the two kilowatt values in a G/P model be used interchangeably?

No. The manual assigns different motor-current and overload ratings to general duty and fan/pump duty.

Are HD30 and HD30-ES/ES1 the same controller?

The catalogue lists HD30 as a general industrial inverter and HD30-ES/ES1 as an escalator controller with its own functions.

Sources & editorial review

Company and product facts are drawn from the sources below. The project briefs and procurement notes are VFDMatch editorial analysis. Statutory disclosures establish company records; order-specific technical acceptance uses the applicable product documents.

  1. Official company overview

    HPMONT company introduction

    Industrial/elevator control, university cooperation and contact premises

    Reviewed 2026-10-08
  2. Official corporate history

    HPMONT development milestones

    2011 establishment, barcode tracking, joint training and 2023 manufacturing centre

    Reviewed 2026-10-08
  3. Government publication

    Shenzhen 2024 safety-standardisation review list

    2024 fifth batch, page 1 entry 8: 深圳市海浦蒙特科技有限公司, Xili, Nanshan

    Reviewed 2026-10-08
  4. Manufacturer product page

    HD30 vector-control inverter

    Industrial functions and current headline voltage/power routes

    Reviewed 2026-10-08
  5. Manufacturer manual, applicable to software after version 3.09

    HD30 User Manual V2.4, July 2021

    Printed pages 5–10, 12 and 125–128: G/P ratings, environment, EIO and PIO options

    Reviewed 2026-10-08
  6. Manufacturer application account, 25 August 2023

    HPMONT mining-equipment applications

    Reported crusher, hoist, mill, pump and ventilator installations

    Reviewed 2026-10-08
  7. Official product page

    HD5L elevator-drive controller

    Programmable I/O, encoder-related torque compensation and acceleration/braking features

    Reviewed 2026-10-08
  8. Official product page

    HD30-ES/ES1 escalator controller

    Entrance-sensor input, programmable I/O and module-temperature control

    Reviewed 2026-10-08
  9. Official product navigation

    HPMONT elevator-system catalogue

    Door, drive, integrated controller, emergency and regeneration product groups

    Reviewed 2026-10-08

Ready to define the configuration?

Bring your motor nameplate, load cycle and controller details to the next discussion.

Inquire about HPMONT
ShareLinkedInXFacebookWhatsAppTelegramRedditEmail